98C
Viair
00098
| SKU: | |
|---|---|
| Availability: | |
| Quantity: | |
Omega Bracket
Check Valve
Vibration Isolators
Mounting Hardware
Installation Instruction
PLEASE NOTE:
Use thread sealant for proper installation. Thread tape is not recommended. Properly sealed, recommended torque for 1/8” is 10 ~ 11 ft. lbs. Recommended torque for 1/4” and 3/8” is 16 ~ 18 ft. lbs. Unless otherwise specified, the gallons mentioned on the webpage are all US gallons.
12-VOLT COMPRESSOR - Supply Voltage 13.8 Volts
| PSI | CFM | A | BAR | LPM | A |
|---|---|---|---|---|---|
| 0 | 1.53 | 7 | 0 | 43.5 | 7 |
| 10 | 1.00 | 9 | 1.0 | 28.0 | 9 |
| 20 | 0.95 | 10 | 2.0 | 25.5 | 11 |
| 30 | 0.90 | 11 | 3.0 | 22.7 | 11 |
| 40 | 0.85 | 11 | 4.0 | 20.7 | 12 |
| 50 | 0.77 | 12 | 5.0 | 18.3 | 12 |
| 60 | 0.72 | 12 | 6.0 | 16.3 | 12 |
| 70 | 0.65 | 12 | 7.0 | 13.7 | 12 |
| 80 | 0.60 | 12 | 8.0 | 11.7 | 12 |
| 90 | 0.54 | 12 | 9.0 | 10.0 | 11 |
| 100 | 0.48 | 12 | |||
| 110 | 0.44 | 12 | |||
| 120 | 0.39 | 12 | |||
| 130 | 0.35 | 11 |
| 0.5 GALLON TANK | FILL RATE |
|---|---|
| 0 to 105 PSI | 50 seconds (± 05 seconds) |
| 85 to 105 PSI | 15 seconds (± 03 seconds) |
| 0 to 120 PSI | 1 minute 05 seconds (± 05 seconds) |
| 90 to 120 PSI | 21 seconds (± 03 seconds) |
| 1.0 GALLON TANK | FILL RATE |
| 0 to 105 PSI | 1 minute 40 seconds (± 10 seconds) |
| 85 to 105 PSI | 30 seconds (± 05 seconds) |
| 0 to 120 PSI | 2 minutes 10 seconds (± 10 seconds) |
| 90 to 120 PSI | 45 seconds (± 05 seconds) |